
Technical parameter Maximum Power(W) 80W Optimum Power Voltage(Vmp) 15.90V Optimum Operating Current(Imp) 5.03A Open Circuit Voltage(Voc) 18.58V Short Circuit Current(Isc) 5.59A Mechanical Characteristics Cell Type Monocrystalline 125x125mm (5 inch) No of Cell 36 (4x9pcs) Dimensions 906x670x35mm Weight 7.2KGS Front Glass 3.2mm,High Transmission, Low iron, tempered Glass Junction box IP65 Rated Output Cable TUV 1x4.0mm2/UL12AWG,Length: 900mm Temperature and Coefficients Operating Temperature(°C): -40°C ~ + 85°C Maximum System Voltage: 600V(UL)/1000V(IEC) DC Maximum Rated Current Series: 15A Temperature Coefficients of Pmax: -0.435% [pdf]

The battery cabinet for base station is a special cabinet to provide uninterrupted power supply for communication base stations and related equipment, which can be placed with various types of lead-acid batteries or lithium iron phosphate batteries to provide power supply for base stations and related equipment to ensure continuous operation of base stations without interruption of services under extreme conditions, help customers to improve the comprehensive service capability of upgrading communication system platforms and meet customer needs. [pdf]

This means that the power supply can “start-up” or be “turned-on” with an ambient temperature as low as -40°C (below the -20°C spec) and deliver 100% of its rated power, however, the power supply’s output regulation, hold-up time, ripple & noise, and other specifications cannot be fully guaranteed until the power supply warms up to at least -20°C. [pdf]

Specifically, the temperature control device monitors the temperature inside the energy storage system in real time through the sensor, and when the temperature exceeds the set threshold, the device will start the heat dissipation device, such as fans, heat sinks, etc., to quickly export the heat to ensure that the system temperature is kept within the safe range. [pdf]

In the wireless communication system of large venues, the signal conflict of multiple base stations will seriously affect the communication quality, and the problem of signal conflict of multiple base stations can be solved from multiple dimensions, such as frequency planning, base station layout and parameter adjustment, application of technical means, optimization management and monitoring. [pdf]
We are committed to excellence in solar power plants and energy storage solutions.
With complete control over our manufacturing process, we ensure the highest quality standards in every solar system and energy storage cabinet we deliver.